A 1 kWh power station runs a chest freezer for roughly 4.4 hours. A 3 kWh unit gets you about 13 hours, and a 5 kWh unit about 21, all on the same assumption: a 500 W compressor that is actually running 40% of the time. That cycle, not the watts on the lid sticker, is what sets the clock.
This guide uses the reference chest freezer from our appliance data: 500 W running, 1,000 W to start, and a 0.4 duty cycle.
Why a 500 W freezer draws 200 W
A chest freezer is a cycling load. The compressor runs until the box is cold, shuts off, and waits for the thermostat. In a normal room it might run 20 to 25 minutes out of each hour. The share of time it is actually drawing power is the duty cycle.
Our planning figure is 0.4, so the average draw is:
500 W × 0.4 = 200 W
That 200 W is the number a battery cares about. The 500 W matters only for the brief moment the compressor is on, and the 1,000 W matters only at startup.
The formula for any station is the same one used across the site:
runtime in hours = (battery watt-hours × 0.85) ÷ average draw
The 0.85 is the inverter efficiency, the share of stored DC energy that comes out as household AC. The rest is lost as heat. Over a full day, a freezer at 200 W average uses 200 × 24 = 4,800 watt-hours at the outlet.
Runtime for six real stations
Each row uses the station’s own battery capacity and its 85% usable figure. The last two columns show the freezer alone and the same freezer with a refrigerator added.
| Station | Battery | Usable (× 0.85) | Freezer alone (200 W avg) | Freezer + fridge (480 W avg) |
|---|---|---|---|---|
| Jackery Explorer 1000 v2 | 1,024 Wh | 870 Wh | 4.4 hours | 1.8 hours |
| BLUETTI AC180 | 1,152 Wh | 979 Wh | 4.9 hours | 2.0 hours |
| Jackery Explorer 1500 v2 | 1,536 Wh | 1,306 Wh | 6.5 hours | 2.7 hours |
| Anker SOLIX C2000 Gen 2 | 2,048 Wh | 1,741 Wh | 8.7 hours | 3.6 hours |
| EcoFlow DELTA 3 Ultra Plus | 3,072 Wh | 2,611 Wh | 13.1 hours | 5.4 hours |
| Jackery Explorer 5000 Plus | 5,040 Wh | 4,284 Wh | 21.4 hours | 8.9 hours |
Battery size sets the runtime. The output rating sets what the station can start. Read these as hours of freezer support, not hours of safe food. A closed freezer holds cold for a while after the power stops.
The math on one model
Take the Jackery Explorer 1500 v2 at 1,536 Wh. Multiply by 0.85 for usable energy:
1,536 × 0.85 = 1,305.6 Wh
Divide by the freezer’s 200 W average:
1,305.6 ÷ 200 = 6.528 hours
So about 6.5 hours. Of that time, the compressor is on for roughly 40%, or 2.6 hours, and idle for the other 3.9. The station rests during the idle stretch, then picks the load back up when the thermostat calls for cold.
Add the refrigerator and the average becomes 200 + 280 = 480 W:
1,305.6 ÷ 480 = 2.72 hours
That is 2.7 hours, about 40% of the freezer-only figure, not half. The fridge’s 700 W compressor at a 40% duty cycle pulls more than the freezer does.
Can the station start the compressor?
Runtime only matters if the station can start the motor. Two checks, both from our sizing rules.
The first is running capacity, kept at or under 80% of the station’s rated output. One freezer needs 500 ÷ 0.8 = 625 W of rated running power. The second is surge. The peak for one freezer is its running watts plus its starting jump:
500 + (1,000 − 500) = 1,000 W
All six stations in the table clear both checks with a wide margin. Their continuous ratings start at 1,500 W and their surge ratings at 2,700 W.
The small end is where people get caught. The Jackery Explorer 300 v2 is rated 300 W running and 600 W surge. Its 80% limit is 240 W, below the freezer’s 500 W running draw, and 600 W cannot start a compressor that wants 1,000 W. A bigger battery does not help if the output is too low.
Check the surge number on the spec sheet, not just the battery size. A station can have plenty of watt-hours and still stall the compressor.
Freezer plus refrigerator
Most households want both. The combined load is 500 + 700 = 1,200 W running. Applying the 80% rule:
1,200 ÷ 0.8 = 1,500 W of rated running output
The peak is the running total plus the larger of the two starting jumps. The fridge adds 2,200 − 700 = 1,500 W, the freezer adds 500 W, so only the fridge counts:
1,200 + 1,500 = 2,700 W
That sets the bar for the pair: about 1,500 W continuous and more than 2,700 W of surge. The 1.5 kWh class is the smallest in our table that passes cleanly. The 1 kWh units sit at or near the line, which our calculator would call marginal.
Starting them one at a time lowers the peak. Let the fridge settle, then plug in the freezer. The worst case drops from 2,700 W to 2,200 W, because the two motors no longer start together. It costs you nothing to do this.
Solar recharge, in general terms
Solar can top up a station between compressor cycles, but it is slow. A panel’s rating is a best-case number at full sun. As a planning rule, multiply panel watts by about four good sun hours, then take off a quarter for angle, heat, clouds, and panel losses. A 200 W panel gives roughly 600 Wh a day.
Against the freezer’s 4,800 Wh daily draw, that is about eight panels to break even, before inverter losses. Solar makes more sense for a smaller overnight buffer than for carrying a freezer around the clock. Size the battery to your overnight load first, then add panels to replace what you used. For the alternative, see our guide to running a chest freezer on a generator, where fuel replaces the battery.
Keep the lid shut
A chest freezer holds cold because cold air sits in the box. Every lid opening spills some of it and pulls the compressor back on sooner. Decide what you need in one trip, and use a cooler for drinks so the main lid stays closed.
A full freezer also cycles less than an empty one, because frozen food holds cold and there is less air to re-cool. If you have spare space, fill it with water bottles before the outage. Keep the freezer out of a hot garage if you can, since a warm room raises the duty cycle and shortens every number on this page.
You do not need to run the station in blocks of hours on and off. The thermostat already does that. The station sits mostly idle, then carries the compressor for a few minutes at a time. Enter your freezer, fridge, and anything else you need into the wattage calculator; it applies the same 80% rule, the same peak math, and the same 0.85 efficiency used here.
The generator alternative works by other rules
A battery power station makes no exhaust, so it can run indoors. Keep it dry, leave the vents clear, and do not cover it while it works. Do not put it next to a heat source or in standing water.
A generator is a different machine with different rules. Hardwiring one to the house needs a transfer switch or interlock installed by a licensed electrician. If anyone in the home relies on a medical device, confirm the plan with the device maker or doctor before an outage. For the fridge side of the same question, see how long a power station runs a refrigerator.