The short answer for a flooding basement: a 1/2 HP sump pump draws 1,050 watts while it runs and 2,150 watts for the second or two it starts. On its own, that fits a small 1,850-watt inverter. Add a refrigerator and 10 LED bulbs, which is what most people actually want during a storm, and you need about 2,313 running watts with 3,350 watts of starting power. That last number is the one that matters when the pump kicks on while the fridge is already running.
What a sump pump draws
A 1/2 HP sump pump is a motor, and motors have two wattage numbers. The running number is steady. The starting number is a brief spike caused by the motor coming up to speed against the water in the pit.
| Load | Running watts | Starting watts | Surge above running |
|---|---|---|---|
| Sump pump (1/2 HP) | 1,050 | 2,150 | 1,100 |
| Refrigerator | 700 | 2,200 | 1,500 |
| LED lights (10 bulbs) | 100 | 0 | 0 |
| Total running | 1,850 |
The pump’s surge is 1,100 watts above its running draw. The fridge’s is 1,500. The lights have no surge at all. These are the numbers this guide uses, taken from manufacturer wattage charts.
Why the start surge decides the size
When a pump starts, the motor pulls its heaviest current before the rotor spins up. That spike lasts a moment, but a generator has to survive it without tripping. A unit with enough running watts and too little surge will run the pump fine, then shut down every time the float rises.
Generators publish two ratings for this reason. Rated running watts is what the unit carries all day. Starting watts, sometimes called surge watts, is a short burst, usually measured in seconds. Compare your worst-case peak against the surge rating, not the running rating.
The other rule is headroom. Keep your steady load at or under 80 percent of the generator’s rated running watts. That leaves room for a battery charger you forgot, keeps the unit off its limit, and stops it from running flat out for days.
Worked example: sump, fridge, and lights
Start with the running watts:
- Sump pump: 1,050 W
- Refrigerator: 700 W
- LED lights: 100 W
Add them: 1,050 + 700 + 100 = 1,850 watts running.
Divide by 0.8 to get the smallest rated running capacity: 1,850 ÷ 0.8 = 2,312.5, so 2,313 watts.
Now the peak. The worst moment is everything running while the biggest motor starts. That is the refrigerator, because its surge is 2,200 − 700 = 1,500 watts above its running draw, which is larger than the pump’s 1,100.
Peak = 1,850 + 1,500 = 3,350 watts.
For a cross-check, start the pump last: 700 + 100 + 2,150 = 2,950 watts. The fridge-starting case is still the higher one, so 3,350 is the number to shop with.
So the target is a generator rated at least 2,313 running watts with at least 3,350 watts of surge. Round up when you shop. No one sells a 2,313-watt unit.
Smallest real models that pass
Here are units from manufacturer spec sheets that clear the pump by itself, or the full three-load list.
| Model | Rated running / starting watts | 80% running limit | Pump only | Pump + fridge + lights |
|---|---|---|---|---|
| Champion 2500W Inverter | 1,850 / 2,500 | 1,480 W | Yes | No |
| Generac iQ3500 | 3,000 / 3,500 | 2,400 W | Yes | Yes, tight |
| Westinghouse iGen4000DFc | 3,300 / 4,000 | 2,640 W | Yes | Yes |
| Champion 4500W Dual Fuel Inverter | 3,500 / 4,500 | 2,800 W | Yes | Yes |
| Anker SOLIX C2000 Gen 2 | 2,400 / 4,000 | 1,920 W | Yes | Yes |
Read the last two columns separately. The Champion 2500W Inverter has a 1,480-watt continuous limit, which covers the pump at 1,050 watts but not the 1,850-watt list. It is the smallest unit in this table, and it keeps a basement dry on its own.
The Generac iQ3500 clears 3,350 watts of surge with 150 watts to spare. That is a 4 percent margin, inside the 10 percent band where we call a match marginal rather than comfortable. It works, but do not add a second motor to that list.
The Westinghouse iGen4000DFc and the Champion 4500W Dual Fuel Inverter leave 650 and 1,150 watts of surge headroom. The Champion is rated 3,500 running and 4,500 starting on gasoline, and 3,150 running on propane.
On gasoline, the Generac iQ3500 publishes 14.1 hours at 25 percent load and 8.9 hours at 50 percent load (economy mode) from a 2.6-gallon tank. The 50 percent point is closest to our list: 50 percent of 3,000 is 1,500 watts, and 1,500 × 8.9 = 13,350 watt-hours per tank. At 1,850 watts that is 13,350 ÷ 1,850 ≈ 7.2 hours. Treat that as a rough estimate, since fuel use does not scale perfectly with load.
A power station option, and how long it lasts
A large power station can start a sump pump, and it runs indoors with no exhaust. The Anker SOLIX C2000 Gen 2 is rated 2,400 running and 4,000 starting watts with a 2,048 Wh battery, so it clears both limits for the three-load list.
Runtime uses the pump’s duty cycle, which is the share of time it actually draws power. A sump pump cycled by its float runs roughly 20 percent of the time, about 12 minutes in an hour. So the average draw is 1,050 × 0.2 = 210 watts.
With the inverter efficiency assumption of 0.85: 2,048 × 0.85 = 1,740.8 watt-hours available. Divide by 210: 1,740.8 ÷ 210 ≈ 8.3 hours on the pump alone.
Add the fridge (700 × 0.4 = 280 W average) and the lights (100 W), and the average draw becomes 210 + 280 + 100 = 590 watts. Runtime drops to 1,740.8 ÷ 590 ≈ 3.0 hours.
That is the honest picture. A power station is a good bridge for the pump, not a multi-day plan for the whole basement. It also needs recharging, so plan that before the storm, not during it.
Battery backup sump pumps as an alternative
If the basement is the only thing you are protecting, a battery backup sump pump is a different tool worth knowing about. It is a separate DC pump with its own battery and charger, installed next to the primary pump. It runs when the power is out, with no fuel, no cord, and no carbon monoxide.
It does one job: keep water moving while the grid is down. It does not run your fridge, lights, or router. Check the battery age and test the float before storm season, since a dead battery is the usual reason these systems fail quietly. A licensed plumber or electrician can confirm the setup fits your pit.
Cords and standing water
Keep cords out of standing water, and keep the generator dry.
Before the storm
- Note the pump’s running and starting watts from its label, not the horsepower alone.
- Start the fridge before the pump so their surges do not stack.
- Check the pit and float, and stage cords off the floor, before the storm.
- Run your list through the wattage calculator so the model you buy clears both numbers.