Best generator for a gas furnace

This page contains affiliate links. Specs come from manufacturer data; we did not lab-test these products (how we work). Last verified 2026-11-23.

A gas furnace still needs electricity for its blower motor and control board. The blower is a motor load with a real start surge, and a furnace is hardwired, so plan on a transfer switch or interlock installed by an electrician before winter.

The load we sized for

ApplianceRunning wattsStarting watts
Furnace blower (1/2 HP)8752,350
Refrigerator7002,200
LED lights (10 bulbs)100–

Total running load: 1,675 W. Worst-case peak, with everything running while the biggest motor starts: 3,175 W. To keep the steady load at or under 80 percent of the rating, you need at least 2,094 rated running watts and 3,175 starting watts.

Our picks

Smallest that clears the listQuietestSmallest dual-fuel optionLightest

Westinghouse iGen4000DFc Inverter Generator - Dual Fuel with CO Sensor

3,300 W running · 4,000 W starting · 62.8 lb

  • The lowest-rated unit here that passes both checks: 3,300 running and 4,000 starting watts against your 3,175 W peak.
  • 52 dB (as low as 52 dBA; measurement distance not stated), the lowest published figure among the units that pass. Makers measure at different distances, so treat small gaps as a tie.
  • Runs on gasoline or propane (2,970 running watts on propane), so you can store fuel that does not go stale.
  • 62.8 lb, the lightest unit here that still passes both checks.

See the full math for this model

Manufacturer's official page. We don't earn anything from this link.

Every model we checked

32 models from our catalog, smallest first. "Close call" means a load lands within 10 percent of a limit: it should work, but there is no room to add anything.

ModelRunning / starting80% limitSurge vs peakNoiseVerdict
DuroMax XP2300iH Dual Fuel Inverter Generator with CO Alert1,800 / 2,3001,440 W2,300 / 3,17552 dBNo
Honda EU2200i Inverter Generator1,800 / 2,2001,440 W2,200 / 3,17548 dBNo
Westinghouse iGen2200c Inverter Generator with CO Sensor1,800 / 2,2001,440 W2,200 / 3,17552 dBNo
Champion 2500W Dual Fuel Inverter1,850 / 2,5001,480 W2,500 / 3,17553 dBNo
Champion 2500W Inverter1,850 / 2,5001,480 W2,500 / 3,17553 dBNo
Generac GP2500i Portable Inverter Generator2,200 / 2,5001,760 W2,500 / 3,175–No
Honda EU3200i Inverter Generator2,600 / 3,2002,080 W3,200 / 3,17554 dBClose call
Honda EU3000iS Inverter Generator2,800 / 3,0002,240 W3,000 / 3,17550 dBNo
Generac iQ3500 Portable Inverter Generator3,000 / 3,5002,400 W3,500 / 3,175–Close call
Westinghouse iGen4000DFc Inverter Generator - Dual Fuel with CO Sensor3,300 / 4,0002,640 W4,000 / 3,17552 dBYes
Champion 4500W Electric Start Dual Fuel Inverter3,500 / 4,5002,800 W4,500 / 3,17561 dBYes
Champion 4500W Dual Fuel Open Frame Inverter3,650 / 4,5002,920 W4,500 / 3,17564 dBYes
Generac iQ5200DF Dual Fuel Inverter Generator3,900 / 5,2003,120 W5,200 / 3,175–Yes
Westinghouse iGen5000DFcv Inverter Generator - Dual Fuel with CO Sensor3,900 / 5,0003,120 W5,000 / 3,17552 dBYes
DuroMax XP5500HX Dual Fuel Portable Generator with CO Alert4,500 / 5,5003,600 W5,500 / 3,17569 dBYes
Honda EB5000 Industrial Generator4,500 / 5,0003,600 W5,000 / 3,17563 dBYes
DuroMax XP7000iH Dual Fuel Portable Inverter Generator5,500 / 7,0004,400 W7,000 / 3,17562 dBYes
Honda EB6500 Industrial Generator5,500 / 6,5004,400 W6,500 / 3,17564 dBYes
Honda EU7000iS Inverter Generator5,500 / 7,0004,400 W7,000 / 3,17552 dBYes
Generac GP6500 Portable Generator6,500 / 8,1255,200 W8,125 / 3,175–Yes
Champion 8000W Electric Start Dual Fuel Generator8,000 / 10,0006,400 W10,000 / 3,17574 dBYes
Champion 8000W Electric Start Tri Fuel Generator8,000 / 10,0006,400 W10,000 / 3,17574 dBYes
Generac GP8000E Portable Generator8,000 / 10,0006,400 W10,000 / 3,175–Yes
DuroMax XP11000iH Dual Fuel Portable Inverter Generator9,000 / 11,0007,200 W11,000 / 3,17561 dBYes
Westinghouse iGen12000TFc Inverter Generator - Tri-Fuel with CO Sensor9,000 / 12,0007,200 W12,000 / 3,17564 dBYes
Generac GP9500ETF Tri-Fuel Portable Generator9,500 / 12,5007,600 W12,500 / 3,175–Yes
Westinghouse WGen9500TFc Tri-Fuel Portable Generator with CO Sensor9,500 / 12,5007,600 W12,500 / 3,17574 dBYes
DuroMax XP13000HX Dual Fuel Portable HX Generator with CO Alert10,500 / 13,0008,400 W13,000 / 3,17574 dBYes
DuroMax XP13750HX Dual Fuel Portable HX Generator with CO Alert11,000 / 13,7508,800 W13,750 / 3,17574 dBYes
Westinghouse WGen11500TFc Tri-Fuel Portable Generator with CO Sensor11,500 / 14,5009,200 W14,500 / 3,17574 dBYes
DuroMax XP17500HX Dual Fuel Portable HX Generator with CO Alert13,750 / 17,50011,000 W17,500 / 3,17577 dBYes
Generac GP15500EFI Portable Generator15,500 / 19,30012,400 W19,300 / 3,175–Yes

How we picked

Every figure comes from manufacturer spec pages in our database; we did not test these units. A model passes when your running load fits under 80 percent of its rated running watts and the worst-case peak fits under its starting watts. Picks are chosen only from models that pass both checks with more than a 10 percent margin. The full method is onhow we work.

For the background and the safety side, read Will a generator run a gas furnace?.

Your appliances may differ from these typical figures. Put your own labels into thewattage calculatorto check any model against your own list.

More picks

Check my own list