Best power station for a CPAP

This page contains affiliate links. Specs come from manufacturer data; we did not lab-test these products (how we work). Last verified 2026-11-23.

A CPAP is a small load, so almost any power station can run one. The real question is how many nights you get per charge and how heavy the unit is to move. This list uses a typical 60-watt CPAP without a heated humidifier; check the label on your own machine and ask your doctor or the device maker about your backup plan.

The load we sized for

ApplianceRunning wattsStarting watts
CPAP (no humidifier)60–

Total running load: 60 W. Worst-case peak, with everything running while the biggest motor starts: 60 W. To keep the steady load at or under 80 percent of the rating, you need at least 75 rated running watts and 60 starting watts. Runtime uses each appliance's duty cycle and 85 percent inverter efficiency.

Our picks

Smallest that clears the listLightest

Jackery Explorer 300 v2 Portable Power Station

288 Wh · 300 W output · 600 W surge · 8.2 lb

  • The smallest battery here that passes both checks: 288 Wh, about 4.1 hours on this list.
  • 8.2 lb, the lightest unit here that still passes both checks.

See the full math for this model

Manufacturer's official page. We don't earn anything from this link.

Every model we checked

23 models from our catalog, smallest first. "Close call" means a load lands within 10 percent of a limit: it should work, but there is no room to add anything.

ModelBattery80% limitSurge vs peakRuntimeVerdict
Jackery Explorer 300 v2 Portable Power Station288 Wh240 W600 / 604.1 hYes
BLUETTI Elite 100 V2 Portable Power Station1,024 Wh1,440 W3,600 / 6014.5 hYes
EcoFlow DELTA 31,024 Wh1,440 W3,600 / 6014.5 hYes
Jackery Explorer 1000 v2 Portable Power Station1,024 Wh1,200 W3,000 / 6014.5 hYes
Anker SOLIX C1000 Portable Power Station1,056 Wh1,440 W2,400 / 6015 hYes
BLUETTI AC180 Portable Power Station1,152 Wh1,440 W2,700 / 6016.3 hYes
Jackery Explorer 1000 Plus Portable Power Station1,265 Wh1,600 W4,000 / 6017.9 hYes
Jackery Explorer 1500 v2 Portable Power Station1,536 Wh1,600 W4,000 / 6021.8 hYes
Anker SOLIX S2000 Portable Power Station2,010 Wh1,200 W3,000 / 6028.5 hYes
Jackery Explorer 2000 v2 Portable Power Station2,042 Wh1,760 W4,400 / 6028.9 hYes
Anker SOLIX C2000 Gen 2 Portable Power Station2,048 Wh1,920 W4,000 / 6029 hYes
BLUETTI AC200L Portable Power Station2,048 Wh1,920 W3,600 / 6029 hYes
BLUETTI AC200MAX Expandable Power Station2,048 Wh1,760 W4,800 / 6029 hYes
EcoFlow DELTA 3 Max Plus (2048Wh)2,048 Wh2,400 W6,000 / 6029 hYes
Anker SOLIX F2600 Portable Power Station2,560 Wh1,920 W2,800 / 6036.3 hYes
Anker SOLIX F3000 Portable Power Station3,072 Wh2,880 W7,200 / 6043.5 hYes
EcoFlow DELTA 3 Ultra Plus (3072Wh)3,072 Wh2,880 W7,200 / 6043.5 hYes
EcoFlow DELTA 3000 Gen4 (3072Wh)3,072 Wh2,880 W7,200 / 6043.5 hYes
Jackery HomePower 30003,072 Wh2,880 W7,200 / 6043.5 hYes
EcoFlow DELTA 3800 Gen4 (3763Wh)3,763 Wh2,880 W7,200 / 6053.3 hYes
BLUETTI Elite 400 Portable Power Station3,840 Wh2,080 W5,200 / 6054.4 hYes
EcoFlow DELTA Pro 34,096 Wh3,200 W8,000 / 6058 hYes
Jackery Explorer 5000 Plus5,040 Wh5,760 W14,400 / 6071.4 hYes

How we picked

Every figure comes from manufacturer spec pages in our database; we did not test these units. A model passes when your running load fits under 80 percent of its rated running watts and the worst-case peak fits under its starting watts. Picks are chosen only from models that pass both checks with more than a 10 percent margin. The full method is onhow we work.

For the background and the safety side, read How to run a CPAP during a power outage.

Your appliances may differ from these typical figures. Put your own labels into thewattage calculatorto check any model against your own list.

More picks

Check my own list